DIN-rail mountable,against symmetrical interferences Attenuation curves on request.
หมวดหมู่ : ELECTRONICS IN THE CONTROL CABINET , 
MEF EMC-FILTER 1-PHASE 2-STAGE I:1A,2A,3A,4A,6A,10A,16A U:250 VAC/300 VDC snap on
Current | 1A | 2A | 3A | 4A | 6A | 10A | 16A |
Art.No. | 10460 | 10461 | 10462 | 10463 | 10464 | 10472 | 10466 |
Weight | 0.45 kg | 0.322 kg | 0.45 kg | 0.305 kg | 0.314 kg | 0.317 kg | 0.349 kg |
Operating voltage | max. 250 V AC/300 V DC |
---|---|
Operating frequency | 50...60 Hz |
Consumption | max. 5 mA (250 V AC) |
Overload current | 18 × (IN t) max. 0.5 ms; 1.5 × (IN t) max. 1 min. (1 × per hour) |
Connection cross section | 0.2...6 mm² single core (AWG 24...9); 0.2...4 mm² multiple core (AWG 24...11) |
Climatic category | 25/085/21 (EN 60068-1) |
---|---|
Test isolation voltage | 2.7 kV (L - N), 2 s; 2.1 kV (L - L), 2 s (EN 60939-2) |
Connection | Screw connection, touch protected |
Mounting method | DIN-rail mountable TH35 (EN 60715) |
Dimensions H × W × D | 107×65×39 mm |
Functional description | The single phase 2-stage EMC filters MEF 1/2 are used in the range 0.1...30 MHz to suppress cable carried interference on mains and control cables. The best filter performance is achieved by using short connection wires (suggestion: earth connection < 10 |
---|---|
Application | symmetrical interferences: units with high repetitions of the switching processes, - switch mode P.S.U.s, - phase angle controller, - supply of universal motors, - behind transformers |